PAT testing: checking portable electrical equipment

PAT testing verifies that portable appliances are electrically safe. What the law actually requires, how intervals are set, and the labels that mislead.

How-toP

PAT testing is the inspection and testing of portable electrical equipment. It is among the most misunderstood duties in workplace safety: the law in most jurisdictions requires electrical equipment to be maintained in a safe condition and says almost nothing about testing every item annually, which is a convention that grew up around the duty rather than the duty itself.

What PAT testing actually involves

  • User checks before use, which catch most faults and require no equipment at all.
  • Formal visual inspection by a competent person, which identifies the majority of remaining defects.
  • Combined inspection and testing with an instrument, which finds faults visual inspection cannot — principally insulation and earth continuity problems.
  • A record of what was tested, when, by whom and the result.
  • A decision about interval based on risk rather than on a universal annual cycle.
  • Not a legal requirement to label every item, though labelling is practical.

How intervals should be set

By the environment and the equipment rather than by the calendar. A power tool on a construction site, moved daily and dragged across rubble, warrants frequent checking; a desktop computer that has not moved in three years does not need the same attention, and testing it annually consumes budget that would be better spent on the tools. Published guidance sets out suggested intervals by equipment class and setting, and a business that has read it and written down its own schedule is in a far stronger position than one testing everything annually because that is what the contractor quoted for.

A label showing a test date is not evidence that the item is safe today — it records that it passed on that date. Damage occurring the following week is caught by user checks rather than by the label, which is why the simplest part of the regime is also the most important.

What the records should show

  1. An inventory of equipment within scope, which is the part most businesses do not have.
  2. The date, the result and the tester for each item, with failures and what happened to them.
  3. Items removed from service, rather than silently disappearing from the list.
  4. The reasoning behind the chosen intervals, so an inspector sees a decision rather than a habit.
  5. New equipment entering the register, since items bought between test rounds are the common gap.
  6. Retention aligned with the equipment's life rather than a fixed period.

Ettex Records holds the equipment list with test dates and next-due fields, which makes the overdue list a filter and the inventory question answerable. The same register carries other inspection cycles, since in practice they are reviewed together.

Frequently asked

Is annual PAT testing a legal requirement?

In most jurisdictions no. The duty is to keep electrical equipment safe, and intervals should follow risk — annual testing of everything is a convention rather than the law.

What catches most faults?

User checks before use, followed by formal visual inspection. Instrument testing finds the remainder, principally insulation and earth continuity defects.

Does a test label mean the item is safe?

Only that it passed on that date. Damage since then is caught by user checks, which is why they matter more than the label.

MI
Written by Maria I.

Part of the Ettex team — writing about product, engineering and the future of work.