← All postsHow-to

Travel distance: how far people walk to reach safety

Travel distance governs escape route design. How it is measured, why single-direction limits are shorter, and what office changes quietly breach it.

How-toT

Travel distance is how far somebody must walk from any point in a building to reach a protected escape route or final exit. It is the number most fire strategies are built around, and it is the one most frequently breached by changes nobody considered a fire matter.

How travel distance is measured

  • Along the actual route a person would walk, not in a straight line through walls and desks.
  • From the furthest point somebody might reasonably occupy, not from the middle of the room.
  • To a protected stairway, a different compartment, or a final exit — not merely to the room door.
  • Around fixed furniture and equipment, which is why layout changes affect it.
  • With permitted distances varying by building use and occupancy risk.
  • Shorter where escape is possible in only one direction.

Why single-direction limits are shorter

Because a fire in the wrong place removes the only way out. Where people can turn either way, a fire blocking one route still leaves the other; where there is only one direction of travel, the permitted distance is cut sharply — often to less than half — precisely because there is no alternative. Dead ends are therefore the most constrained part of any layout, and the easiest to create by accident when somebody partitions an open floor.

A desk move can breach the fire strategy. Extending a dead end or placing a workstation beyond the permitted distance changes compliance without any construction work, and nobody involved will have thought to check — which is why layout changes should be reviewed against the strategy as a matter of routine.

What quietly breaches it

  1. New partitions creating dead ends on previously open floors.
  2. Storage or equipment narrowing a route so the walked path lengthens.
  3. Doors locked or made one-way for security, removing a direction of escape.
  4. Increased occupancy, which changes the permitted figures as well as the exit widths needed.
  5. Change of use — sleeping accommodation and high-risk processes have much tighter limits.
  6. Temporary works and refurbishment hoardings, which are rarely assessed at all.
  7. Reviewing distances after every alteration, which is the only control that catches these.

Ettex Records keeps the fire strategy with its assumed distances alongside the alterations log, so a layout change can be checked against what the design assumed. The route inspections that confirm escape routes stay clear belong in the same register.

Frequently asked

How is travel distance measured?

Along the route a person would actually walk, around fixed furniture, from the furthest occupied point to a protected route or final exit.

Why are dead-end distances shorter?

Because a fire blocking the single available direction removes the only escape, so permitted distances are cut sharply — often by more than half.

Can an office layout change breach it?

Yes. New partitions, storage or locked doors can extend travel distances or create dead ends without any construction work.